15 ш - перевести

ICARELIFE Operating Room Control Panel
https://icarelife.com/products..../operating-room-cont

ICARELIFE operating room control panel demo
Integrated Sensor Options
Expand your control panel room with high-precision SIEMENS instrumentation for total environment monitoring

Siemens white temperature sensor with probe
Air Duct Humdity & Temp Sensor​
Model: SIEMENS QFM1660
Relative Humidity Digital Output: DC 0–10V
Temperature Digital Output: DC 0–10V
Measurement Accuracy: <±0.8°C @ 25°C / ±5% r.h.
Applicable Temperature & Humidity Range: 0–50°C / 10–90% r.h. (Non-condensing)
Operating Voltage: AC 24V or DC 19-30V

Air Room Humdity & Temp Sensor
Model: SIEMENS QFM 2068
Operating voltage: AC/DC 13.5…35 V
Measuring range, temperature: -15…50 °C
Measurement range humidity: 0…95 % r.h.
Measurement accuracy: 23 °C:23 % r.h., 0…95 % r.h.:±5 % r.h.
Time constant: 20s
Signal output temperature: DC 0…10V, DC 4…20mA, LG-Ni1000
Signal output humidity: DC 0…10 V, DC 4…20 mA

Differential Pressure Sensor
Model: SIEMENS QFM 2030
Operating Voltage: AC 24V or DC 13.5–33V
Signal Output: DC 0–10V
Zero Point Adjustment
Calibrated and Temperature-compensated Measurement Signal

Centralizing Control for a Modern Modular Operating Theatre
The Challenge
The facility struggled with fragmented controls—separate switches for lighting, HVAC, and gas alarms created a cluttered wall and slowed down emergency response times for the surgical team.

The ICARELIFE Solution
We installed our 32" Android-based Capacitive Touch Panel, integrating all critical room functions—including Siemens-grade environment sensors and medical gas alarms—into one seamless glass interface.

Medical Gas Pressure Sensor
Measurement Range: -0.1MPa to 100MPa (Optional)
Operating Voltage: Universal for 220V and 380V
Accuracy: 1.6 Grade
Ambient Temperature: -40°C to 70°C
Relative Humidity: ≤85%
Installation for panel without writing desk
Precision Installation Guide: Flush-Mount Specifications
Follow these exact dimensions to ensure a perfectly flush, hygienic seal with the operating room wall system.

STEP 1: THE WALL CUT-OUT
Wall Opening Size
826 x 554 x 200 mm

Must be prepared prior to installation.
STEP 2: THE BODY
Panel Box Size
821 x 549 x 200 mm

Fits securely within the wall opening.
STEP 3: THE INTERFACE
Visible Glass Screen
813 x 541 mm

Edge-to-edge toughened glass for easy cleaning.

Installation Tip: Ensure a 5mm clearance around the panel box for easy adjustment and final sealant application. Gross shipping weight: 55kg.

Installation for panel with writing desk
Precision Installation Guide: Flush-Mount Dimensions
Follow the recommended dimensions below to achieve a flush, hygienic installation suitable for operating rooms and cleanroom wall systems.

STEP 1: WALL PREPARATION
Recommended Wall Cut-out Size
826 × 934 × 300 mm

Wall opening to be completed before panel installation.
STEP 2: HOUSING
Rear Box Size
821 × 929 × 300 mm

Installed inside the wall cavity and fixed to structure.
STEP 3: INTERFACE
Visible Glass Touch Screen
813 × 541 mm

Flush front glass surface for easy cleaning and disinfection.

Frequently Asked Questions (FAQ)
How do I monitor and control Temperature and Humidity data?
ICARELIFE provides two professional methods for environmental management:
Option 1 (Direct Monitoring): By connecting 3rd-party high-precision sensors (such as the SIEMENS QFM166, the panel provides real-time data visualization on the 32" touchscreen.
Option 2 (Full Bi-Directional Control): By integrating with the hospital HVAC PLC system via MODBUS RS-485 protocol, the panel allows surgical staff to both monitor and adjust temperature and humidity set-points directly from the glass interface.

Why is a touchscreen safer than traditional push-button panels?
Traditional mechanical buttons create microscopic "dead zones" where pathogens can colonize. Our Android-based capacitive glass interface is completely flat and seamless, eliminating the gaps where biofilm develops. It is 100% wipe-clean and resistant to standard medical-grade disinfectants.

What are the advantages of the Android-based Operating System?
Most legacy panels are "hard-coded" and cannot be updated. The ICARELIFE Android platform is future-proof, allowing for easy software updates, interface customization, and smoother multi-system backups. This ensures your OR technology stays modern as hospital systems evolve.

Can this panel manage OR lighting dimmers?
Yes. While standard configurations offer ON/OFF control, we can integrate dimming modules upon request. We support DMX 512 protocols for surgical lighting and can facilitate DALI protocol testing to ensure your shadowless lamps are fully controllable from the central station.

Is the OR Control Panel classified as a medical device?
The theatre control panel is classified as hospital infrastructure/control equipment, not a medical device, because it manages the surgical environment and does not perform a clinical function on the patient.

As one of ot equipment suppliers, we will do our best to meet all the needs of customers.

image

Install Palscity app

Android IOS